Electrical Specifications - Inverter
|
| Model |
TN-1500-112F |
TN-1500-124F |
| Continuous power (max rated) |
1500 W |
1500 W |
| Surge power |
1725 W for 180 seconds / 2250 W for 10 seconds /
3000 watts for 30 cycles |
| AC voltage |
Factory Setting 110 VAC (100/110/115/120 selectable) |
| Waveform |
True sine wave (THD < 3%) at rated input voltage |
| Frequency |
60 Hz ± 0.1% (50 / 60 Hz selectable) |
| Transfer time |
< 10 ms |
< 10 ms |
| Saving mode |
Load 5 W will be changed to standby mode |
| Battery voltage |
12 V |
24 V |
| Voltage range |
10.5 VDC ~ 15 VDC |
21 VDC ~ 30 VDC |
DC current |
150 A |
75 A |
| No load draw (standby) |
18 W |
18 W |
| No load draw (switch off) |
1 mA |
1 mA |
| Efficiency |
87% |
89% |
| Battery types |
Open & sealed lead acid |
| |
Electrical Specifications - Charger
|
| Model |
TN-1500-112F |
TN-1500-124F |
| AC charge current |
5.5 A ± 0.5 A |
2.7 A ± 0.4 A |
| AC charge voltage |
14.3 V ± 4% |
28.5 V ± 4% |
| Solar open circuit voltage (max) |
25 V |
45 V |
| Solar charge current (max) |
30 A |
30 A |
| Vmax charge voltage |
14.3 V ± 4% |
28.5 V ± 4% |
| |
Protection Specifications
|
| Model |
TN-1500-112F |
TN-1500-124F |
| Low voltage alarm |
11.3 ± 4% |
22.5 ± 4% |
| Low voltage shutdown |
10.5 ± 4% |
21.0 ± 4% |
| Over temperature |
180° F ± 8 ° F (82° C ± 5° C) |
180° F ± 8 ° F (82° C ± 5° C) |
| Output short-circuit |
Yes |
Yes |
| Overload |
105 ~ 115% load for 180 sec, 115 ~ 150% load for 10 sec |
| Circuit breaker |
20 A |
20 A |
| GFCI protection |
Yes |
Yes |
| |
General Specifications
|
| Model |
TN-1500-112F |
TN-1500-124F |
| Operating temperature range |
32 ~ 104° F (0 ~ 40° C) @ 100% load; 140° F ( 60° C) @ 50% |
| Working humidity |
20% ~ 90% RH non-condensing |
| Storage temperature / humidity |
-22 ~ 158° F (-30 ~ 70° C) / 10 ~ 95% RH |
| Dimensions |
16.5" x 8.7" x 3.5" (420 x 220 x 88 mm) |
| Inverter-charger weight |
15 lbs |
15 lbs |
| Shipping weight |
18 lbs |
18 lbs |
| Warranty |
Two years |
Two years |
| |
Regulatory Approvals
|
| Model |
TN-1500-112F |
TN-1500-124F |
| Safety standards |
UL 458 |
| EMI Conduction & Radiation |
Compliance to FCC class A |